Untitled Document
   
Untitled Document
 
Car Lift
Wheel Aligner
Wheel balancer
Tire Changer
Gas analyzer
Diesel smoke tester
ATF changer
Carbon cleaner/
Gasoline injecter
Battery tester & charger
Spotwelder
Refrigent recycler
Jack & pinpress etc
Fuel injection
pump tester etc
Lubrication equipment
Brake lathe
Vehicle diagnosis system
Generator
Air compressor
Car washing machine
Car mat cleaner
Reconditioning equipment
Diesel engine generator | Digital diesel generator | Welding generator |
Diesel generator | Sound proof generator | Alternators |
Gas tubine generator | Power plant engineering |    

 
   
 
 

We have supplied various generators with high reliability of more than 40 years experience to all over the world.
With our great experience in the development and production of rotating machines, we has realized suitable generators for a variety of engines, gaining the recognition of their excellence by customers.

Strong structure and durability
Perfect protective device
Outstanding maintenance service to conform to quality management program

Our generator can be used for various purpose from general to special purpose such as building(hotel, bank), industrial, military, manufacturing plant, construction etc.
Having Microprocessor diagnosis, it can control and change timer, operating sequence, alert etc in software.
It can add the function of real-time diagnosis, control unit and electric control panel module. (Optional)


 

Special procurements winding
AVR is become independent from generator output and it is not influenced by outside load condition supplies stable power supply to exciter.
AVR is defended perfectly about voltage regulation by switchgear of load and thyristor loads.
Because do motor starting loads, generator does not receive any effects by voltage drop even if it is engaged doing sudden wiring brush of and so on.
If one load of generator was broken in cut off, other loads can be operated safely, because only engaged circuit breaker is operated.
Extra voltage supplying for drop voltage in an accident.

 

Class H insulation system
Generator used class h insulation, and there is letdown in dust, moisture, salt content etc. because using AIW in case of copper wire specially.
Generator is safe in overload of 110%.
Generator is designed to use to ambient temperature 50 degree.
Life is semi-permanent by special procurements insulation.

 

2/3 pitch stator winding
Because 3 harmonics are not happened, communication obstacle is less.
About single phase load, voltage waveform is good.
Influence about non-linear load is less.

 

Lead wire
Lead wire withdraws leader 12 lines and because alteration of low tension, high tension, single phase connection, delta connection etc/ is possible, the range of application is wide.
Due to withdraw coil directly, there is no welding resistance when withdraw rescue and there is no worry of voltage breakdown.

  Automatic voltage regulator
Is low speed protector.
When this unit is 60Hz, it is 56Hz, and low speed protector prevents generator and AVRs damage because reducing output voltage of generator in case use by 46Hz low when is 50Hz.

Is overload protector.
Digital control generator
Engine generator control panel features and function

Automatic engine starting and stopping
Custom graphical icon type LCD display
PC configurable via Ms-windows based software
Provides engine instrumentation
Provides generator output instrumentation
Simple selector switch controlled operation
Real time diagnostics via Ms-windows
configurable digital input
Configurable relay output
configurable timer settings
Display scroll
Generator volts L1-N, L2-N, L3-N
Generator volts L1-L2, L2-L3, L3-L1
Generator amps L1, L2, L3
Generator frequency Hz
Engine speed RPM
Engine oil pressure (PSI & Bar)
Engine temperature (C & ơF)
Plant battery volts
Engine hours run

Alarm
Generator over/under volts (AC/DC)
Generator over/under frequency (Hz)
Engine over/under speed
Emergency stop
Low oil pressure
High coolant temperature
Fail to start (over crank)
Electrical trip
Generator high current

Option
Real-time diagnostics device & relay expansion module
Real-time diagnostics using personal computer


Brushelss-three phase synchronous generator, rating voltage 380V/220V, pole 4P

<table1>

  model unit BDS-20 BSA-26 BSA-50 BSA-60  BSA-85

generator

stanebyPower
(50hz~60Hz)
 KW  22/26 40/50 48/60 72/85 101/115
  Prime Power
(50hz~60hz)
kW  15/18 20/24 25/45 43/55 64/77
    L  mm  1905 1800 1872 2102 2114
  Dimension   M mm  750 750 750 760 850
    H mm  1113 1040 1167 1172 1371
  Fuel Tank Capacity  Ƨ 30 40 50 70 120
  Dry Weight  kg 586 710 835 1032.4 1353
               
Engine Model  Unit  DC24 DB33 PO34TI  DB58

D1146

  stanebyPower
(50hz~60Hz)
PS  24/34 39/47 65/82 95/80 143/116
  Prime Power
(50hz~60hz)
 PS  25/31 35/43 57/75 73/87  105/130
  Displacement  cc   2369 3268 3268 5785 8071

  model unit BSA-115 BSA-170 BSA-200  BSA-250

generator

stanebyPower
(50hz~60Hz)
 KW 145/170 175/200 -/250 242/275
Prime Power
(50hz~60hz)
kW 91/105 131/155 155/182 -/227
  L mm 2137 2470 2556 2850
Dimension   M mm 850 900 900 1000
  H mm  1360 1415 1525 1700
Fuel Tank Capacity   120 160 150 230
Dry Weight  kg 1483 1794 1907 2280
Engine Model  Unit D1146T DE12T PO86TI P126TI
stanebyPower
(50hz~60Hz)
PS 187/160 270/226 303/270 343/375

Prime Power
(50hz~60hz)

PS 145/170 205/245 240/279  304/343
Displacement  cc  8071 11051 8071 11051
  model unit BSA-115 BSA-170 BSA-200  BSA-250

generator

stanebyPower
(50hz~60Hz)
 KW 145/170 175/200 -/250 242/275
Prime Power
(50hz~60hz)
kW 91/105 131/155 155/182 -/227
  L mm 2137 2470 2556 2850
Dimension   M mm 850 900 900 1000
  H mm  1360 1415 1525 1700
Fuel Tank Capacity   120 160 150 230
Dry Weight  kg 1483 1794 1907 2280
Engine Model  Unit D1146T DE12T PO86TI P126TI
stanebyPower
(50hz~60Hz)
PS 187/160 270/226 303/270 343/375

Prime Power
(50hz~60hz)

PS 145/170 205/245 240/279  304/343
Displacement  cc  8071 11051 8071 11051

<table2>

  model BSA-275 BSA-300 BSA-320 BSA-360 BSA-400

generator

stanebyPower
(50hz~60Hz)
-/300 284/320 326/360 369/400 447/500
Prime Power
(50hz~60hz)
220/250 -/- 258/290 293/327 323/364
Dimension   L 2850 2920 2830 2900 2900
M 1000 1000 1390 1390 1390
H 1700 1560 1950 1950 1950
Fuel Tank capacity 230 330 330 330 330
Dry Weight 2280 2340 2680 2875 2875
Engine Model P158LE-i  p158le-2 p023le1   P158LE-1  P158LE
stanebyPower
(50hz~60Hz)
370/405 -/465 437/491 492/546 563/602
Prime Power
(50hz~60hz)
 328/378  -/422 399/447 444/498 494/547
Displacement 11051 11051 14618 14618 14618

  model BSA-450 BMA-500 BMA-550 BMA-600

generator

stanebyPower
(50hz~60Hz)
 395/450  447/500  -/550 520/600 
Prime Power
(50hz~60hz)
359/409 398/455 -/500 480/545
Dimension   L 3070 3130 3355 3355
M 1390 1390 1390 1390
H 1950 1950 1820 1820
Fuel Tank Capacity 330 330 - -
Dry Weight 3251 3371 4010 4010
Engine Model  1bole-1  1bole  p222le-2 p222le
stanebyPower
(50hz~60Hz)
601/677 674/734 752/850 781/883
Prime Power
(50hz~60hz)
548/617 602/676 696/765 723/803
Displacement 18273 18273 21927 21927


Supply item
Silencer, battery charger, battery, bellows, basis tools, battery cable terminal filter(fuel and oil), generator manual, engine manual

Option
Vibration-isolation spring, breaker control panel, fuel tank (490 / 990)
Real time diagnosis software & interface system, relay expansion module


*The manufacture reserves the right to change the product specifications without notice and liability.